1 |
Faculty of Science and Technology |
School of Mechanical and Manufacturing Sciences |
AI Based Six DOF Articulated Robot |
230V 6 Amp power supply (3 qty), Proper Earthing (≤2Vac between Neutral and Earth, 2 separate preferred), Entrance door ≥1.2m wide, Table size approx. 1060mm x 1000mm x 1630mm, Extension board (if needed), LAN cable 3m (1 qty) |
Automated manipulation, assembly, welding, painting, pick and place operations, research in robotics and AI. Six degrees of freedom allow for complex movements.
|
2 |
Faculty of Science and Technology |
School of Mechanical and Manufacturing Sciences |
AI Based Four DOF SCARA Robot Cell |
230V 6 Amp power supply (3 qty), Proper Earthing (≤2Vac between Neutral and Earth, 2 separate preferred), Entrance door ≥1.2m wide, Extension board (if needed), LAN cable 3m (1 qty) |
High-speed, precise pick-and-place operations, assembly, material handling, particularly suited for planar movements. SCARA (Selective Compliance Assembly Robot Arm) robots are efficient for tasks in a plane. |
3 |
Faculty of Science and Technology |
School of Mechanical and Manufacturing Sciences |
Motion Control Experimental Setup |
230V 6 Amp power supply (3 qty), Proper Earthing (≤2Vac between Neutral and Earth), Extension board (if needed), LAN cable 3m (1 qty) |
Investigation and experimentation with different motion control techniques, including servo motors, stepper motors, and various control algorithms. Learning about feedback systems and automation.
|
4 |
Faculty of Science and Technology |
School of Mechanical and Manufacturing Sciences |
IOT, PLC & Manual based Electro-Pneumatic System |
230V 6 Amp power supply (3 qty), Proper Earthing (≤2Vac between Neutral and Earth), Extension board (if needed), LAN cable 3m (1 qty) |
Learning the principles of pneumatics, PLC control, and IoT integration in automated systems. Combines manual control with automated sequences using PLCs and incorporates IoT for monitoring and data acquisition. |
5 |
Faculty of Science and Technology |
School of Mechanical and Manufacturing Sciences |
IOT, PLC & Manual based Hydraulic System |
230V 6 Amp power supply (3 qty), 230V Single Phase 16A power socket (1 qty), Proper Earthing (≤2Vac between Neutral and Earth), Extension board (if needed), LAN cable 3m (1 qty) |
Similar to the electro-pneumatic system, but uses hydraulics instead of pneumatics. Hydraulic systems are used for applications requiring higher forces and power. Learning about hydraulic principles, PLC control, and IoT integration.
|
6 |
Faculty of Science and Technology |
School of Civil and Environmental Sciences |
e-Builder Small |
Gantry Based 3D printer; X-1000mm x Y-1000mm x Z-1000mm print volume; 3 axis; Two Interchangeable sliding pellet bed platform; +/- 0.5mm precision; 0.2mm position repeatability; 10-50mm layer resolution; 10-150mm/sec print speed; X-150mm/sec, Y-150mm/sec, Z-60mm/sec max movement speed; Hybrid Stepper Motors; Low Backlash planetary Gearbox; 25mm width Linear Guides; Racks and Pinions; Interchangeable nozzles; Screw Extruder with 10-15kg hopper capacity; Metered Pumping System; Prints Concrete/Mortar/Clay/Ceramic Paste, etc.; 1-year warranty |
Laboratory scale concrete 3D printing, prototyping, research, testing, and in-house production. |
7 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Fourier Transform Infrared Spectrophotometer (FTIR) |
Wavelength range: 4000-400 cm⁻¹, Resolution: 0.5 cm⁻¹ |
Chemical analysis, material identification |
8 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
High Performance Liquid Chromatography (HPLC) |
Flow rate: 0.001-10 mL/min, Pressure limit: 6000 psi |
Separation, identification, and quantification of components in a mixture |
9 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
UV-Visible Spectrophotometer |
Wavelength range: 190-1100 nm, Bandwidth: 1 nm |
Quantitative analysis of solutions |
10 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Dissolution Test Apparatus |
Speed: 25-250 rpm, Temperature control: 25-45°C |
Testing drug release from pharmaceutical dosage forms |
11 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Abbe's Refractometer |
Refractive index range: 1.3000-1.7000, Accuracy: ±0.0002 |
Measuring refractive index of liquids |
12 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Colorimeter |
Wavelength range: 400-700 nm, Accuracy: ±1 nm |
Color measurement and analysis |
13 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Polarimeter |
Angle range: -180° to +180°, Accuracy: ±0.01° |
Measuring optical rotation of chiral compounds |
14 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Analytical Digital Balance |
Capacity: 200 g, Readability: 0.0001 g |
Precise weighing of small samples |
15 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Brookfield Viscometer |
Speed range: 0.01-250 rpm, Torque range: 0.1-100% |
Measuring viscosity of fluids |
16 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Biochemistry Analyzer iCHEM168 |
Multiple test panels, Throughput: up to 200 tests/hour |
Clinical diagnostics and biochemical analysis |
17 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Digital pH Cum Potential Meter |
pH range: 0-14, Accuracy: ±0.01 pH |
Measuring pH and potential of solutions |
18 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Digital Conductivity Meter |
Conductivity range: 0-200 mS/cm, Accuracy: ±1% |
Measuring electrical conductivity of solutions |
19 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Nepheloturbidity Meter |
Range: 0-1000 NTU, Accuracy: ±2% |
Measuring turbidity in liquids |
20 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Digital Turbidity Meter |
Range: 0-1000 NTU, Resolution: 0.01 NTU |
Measuring turbidity in water and other liquids |
21 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Flame Photometer |
Detection range: 0-1000 ppm, Accuracy: ±1% |
Measuring concentration of metal ions in solutions |
22 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Photo-Fluorimeter |
Excitation wavelength: 250-700 nm, Emission wavelength: 280-800 nm |
Fluorescence analysis of samples |
23 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Digital pH meter |
pH range: 0-14, Resolution: 0.01 pH |
Measuring pH of solutions |
24 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Sonicator |
Frequency: 20 kHz, Power: 100-500 W |
Cell disruption, mixing, and degassing |
25 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Digital pH meter |
Chemiline (Make) |
Measures the pH of a solution. It is used in chemical analysis and environmental monitoring. |
26 |
Faculty of Health Sciences |
School of Pharmaceutical Science |
Sonicator |
Rolex (Make) |
Uses ultrasonic waves to agitate a sample. It is used to disrupt cells, dissolve substances, and degas liquids. |